{"id":925,"date":"2023-10-11T11:26:36","date_gmt":"2023-10-11T03:26:36","guid":{"rendered":"https:\/\/www.xthbm.com\/?post_type=product&#038;p=925"},"modified":"2023-11-27T11:45:28","modified_gmt":"2023-11-27T03:45:28","slug":"split-type-electromagnetic-flowmeter","status":"publish","type":"product","link":"https:\/\/www.xthbm.com\/es\/producto\/split-type-electromagnetic-flowmeter\/","title":{"rendered":"Caudal\u00edmetro electromagn\u00e9tico de tipo partido"},"content":{"rendered":"<h3 class=\"magic-1\" data-spm-anchor-id=\"a2700.details.0.i56.75baa65dfP1XJT\"><b><span class=\"magic-12\">Caracter\u00edsticas<\/span><\/b><\/h3>\n<div class=\"magic-4\">\n<div class=\"magic-5\">\n<div class=\"magic-6\"><span data-spm-anchor-id=\"a2700.details.0.i57.75baa65dfP1XJT\">\u25b2 There are no moving parts and no choke parts in the pipeline, and there is almost no additional pressure loss in the measurement.<br \/>\n\u25b2 The measurement result has nothing to do with physical parameters such as velocity distribution, fluid pressure, temperature, density, viscosity, etc.<br \/>\n\u25b2 At the scene, the range can be modified online according to the actual needs of the user.<br \/>\n\u25b2 High-definition backlit LCD display, full Chinese menu operation, easy to use, simple operation, easy to learn and understand.<\/span><\/p>\n<div>\u25b2 Using 16-bit embedded microprocessor, fast operation speed, high accuracy, programmable frequency low frequency rectangular wave excitation, improve the stability of flow measurement, and low power consumption.<br \/>\n\u25b2 Full digital processing, strong anti-interference ability, reliable measurement, high accuracy, flow measurement range up to 150: 1.<\/div>\n<\/div>\n<div>\n<h3><strong><span data-spm-anchor-id=\"a2700.details.0.i67.66e55784LjnE18\">Working principle<\/span><\/strong><\/h3>\n<p><span data-spm-anchor-id=\"a2700.details.0.i69.66e55784LjnE18\">Electromagnetic flow meters are flowmeters that measure flow according to Faraday&#8217;s law of electromagnetic induction. Electromagnetic flowmeters have the advantage of minimal pressure loss and a large range of measurable flow rates. The ratio of the maximum flow rate to the minimum flow rate is generally more than 20:1. The applicable industrial tube diameter is wide, up to 3 meters. The output signal and the measured flow rate are linear, and the accuracy is high. The conductivity can be measured \u22655\u03bcs\/cm. Acid, alkali, salt solution, water, sewage, corrosive liquids, and fluid flow of mud, pulp, pulp, etc. However, it cannot measure the flow of gas, steam, and pure water.<\/span><\/p>\n<h3><strong><span data-spm-anchor-id=\"a2700.details.0.i71.66e55784LjnE18\">The main technical indicators:<\/span><\/strong><\/h3>\n<table border=\"1\">\n<tbody>\n<tr>\n<td>\u00a0Nominal diameter<\/td>\n<td>\u00a0DN15~DN2000<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Accuracy<\/td>\n<td>\u00a0\u00b10.2%,\u00b10.3%,\u00b10.5%<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Measurement range\u00a0 \u00a0(flow rate)<\/td>\n<td>\u00a00.01m\/s~15m\/s<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Conductivity of medium<\/td>\n<td>\u00a0more than 5\u03bcS\/cm<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Nominal pressure<\/td>\n<td>\u00a00.6MPa,1.0MPa,4.0MPa<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Protection grade<\/td>\n<td>\u00a0IP65,IP67,IP68<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Electrode material<\/td>\n<td>\u00a0Stainless steel 316L,Hastelloy B, Hastelloy C, Titanium\u00a0 \u00a0alloy, Tantalum alloy, Platinum-iridium alloy, Stainless\u00a0 \u00a0steel-coated tungsten carbide and other special\u00a0 \u00a0material .<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Lining material<\/td>\n<td>\u00a0Neoprene,Polyurethane rubber,natural rubber, nitrile\u00a0 \u00a0rubber, Teflon(PFA),Polytetrafluoroethylene(PTFE),\u00a0 \u00a0fluorinated ethylene propylene (FEP OR F46), ceramics.<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Conexi\u00f3n<\/td>\n<td>\u00a0Flange connection [GB\/T9119-2010 standard]<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Ambient temperature<\/td>\n<td>\u00a0-10\u2103~50\u2103<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Power supply<\/td>\n<td>\u00a0AC220V\/DC24V\/DC3.6V<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Signal output<\/td>\n<td>\u00a0Analog 4mA-20mA, 0Hz~ 5 KHz frequency, two alarm\u00a0 \u00a0outputs: high limit alarm and low limit alarm<\/td>\n<\/tr>\n<tr>\n<td>\u00a0Communication<\/td>\n<td>\u00a0RS485,RS232,MODBUS,HART,PROFIBUS-DP (\u00a0 \u00a0OPTIONAL)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p><strong>Expression of electromagnetic flowmeter caliber:<\/strong><br \/>\n<span data-spm-anchor-id=\"a2700.details.0.i72.66e55784LjnE18\">The expression of the electromagnetic flowmeter caliber is three digits, the first two are the first and the second.<\/span><br \/>\nNumber of caliber, the third digit means number of 0.<br \/>\nFor example, code 150 indicates a caliber of 15 mm; code 151 indicates a diameter of 150 mm; code 152 indicates a caliber of 1500.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-932\" src=\"http:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/Hd7a9cc1d0fe549638442b758f19aed3cf.jpg\" alt=\"\" width=\"750\" height=\"583\" srcset=\"https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/Hd7a9cc1d0fe549638442b758f19aed3cf.jpg 750w, https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/Hd7a9cc1d0fe549638442b758f19aed3cf-300x233.jpg 300w, https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/Hd7a9cc1d0fe549638442b758f19aed3cf-600x466.jpg 600w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-933\" src=\"http:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/H661d0101fd9b4ecfb8578d8a91daf7503.jpg\" alt=\"\" width=\"750\" height=\"567\" srcset=\"https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/H661d0101fd9b4ecfb8578d8a91daf7503.jpg 750w, https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/H661d0101fd9b4ecfb8578d8a91daf7503-300x227.jpg 300w, https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/H661d0101fd9b4ecfb8578d8a91daf7503-600x454.jpg 600w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-934\" src=\"http:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/H2665c439e66748598cdaeff0decae36dE.jpg\" alt=\"\" width=\"750\" height=\"899\" srcset=\"https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/H2665c439e66748598cdaeff0decae36dE.jpg 750w, https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/H2665c439e66748598cdaeff0decae36dE-300x360.jpg 300w, https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/H2665c439e66748598cdaeff0decae36dE-600x719.jpg 600w, https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/H2665c439e66748598cdaeff0decae36dE-250x300.jpg 250w\" sizes=\"auto, (max-width: 750px) 100vw, 750px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-935\" src=\"http:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/\u5fae\u4fe1\u56fe\u7247_20231011112218.png\" alt=\"\" width=\"747\" height=\"767\" srcset=\"https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/\u5fae\u4fe1\u56fe\u7247_20231011112218.png 747w, https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/\u5fae\u4fe1\u56fe\u7247_20231011112218-300x308.png 300w, https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/\u5fae\u4fe1\u56fe\u7247_20231011112218-600x616.png 600w, https:\/\/www.xthbm.com\/wp-content\/uploads\/2023\/10\/\u5fae\u4fe1\u56fe\u7247_20231011112218-292x300.png 292w\" sizes=\"auto, (max-width: 747px) 100vw, 747px\" \/><\/p>\n<\/div>\n<div class=\"magic-6\">\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<div><\/div>\n<\/div>\n<\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<h6>Caudal\u00edmetro electromagn\u00e9tico de tipo partido<\/h6>\n<p>Electromagnetic flowmeter can be used to measure the volume flow of conductive fluid in a closed pipeline. It is widely applied in the flow measurement and control in the fields of chemical and petroleum industry, metallurgy industry, water and wastewater, agriculture and irrigation, paper making, food and beverage industry and pharmaceutical industry, etc.<\/p>\n<p>When the conductive fluid flows through the measuring tube of the sensor, the voltage signal in direct proportion to the average flow velocity of the fluid will be inducted on the electrodes. The signal is amplified and treated by the transmitter to realize various display functions.<\/p>\n<p>Todos los contadores estar\u00e1n garantizados contra defectos de fabricaci\u00f3n y materiales durante un periodo de un (1) a\u00f1o a partir de la fecha de aceptaci\u00f3n. Los contadores o piezas defectuosos descubiertos dentro de este periodo ser\u00e1n sustituidos sin cargo alguno tras su devoluci\u00f3n a HBM Meters.<\/p>\n[contact-form-7 id=\"1a3abea\" title=\"inquiry\"]","protected":false},"featured_media":926,"template":"","meta":{"_seopress_robots_primary_cat":"","_seopress_titles_title":"","_seopress_titles_desc":"","_seopress_robots_index":"","_joinchat":[]},"product_brand":[],"product_cat":[22],"product_tag":[],"class_list":{"0":"post-925","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-flow-meter","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.xthbm.com\/es\/wp-json\/wp\/v2\/product\/925","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.xthbm.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.xthbm.com\/es\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.xthbm.com\/es\/wp-json\/wp\/v2\/media\/926"}],"wp:attachment":[{"href":"https:\/\/www.xthbm.com\/es\/wp-json\/wp\/v2\/media?parent=925"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.xthbm.com\/es\/wp-json\/wp\/v2\/product_brand?post=925"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.xthbm.com\/es\/wp-json\/wp\/v2\/product_cat?post=925"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.xthbm.com\/es\/wp-json\/wp\/v2\/product_tag?post=925"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}